Model
|
Stable Rejection Rate
|
Minimum Rejection Rate
|
Average Permeated Flow(GPD)
|
C-MAT1812-50G
|
98%
|
96%
|
50
|
Testing Conditions Feedwater ------------------------------------------ 60Psi(0.41MPa) Feedwater Temperature ---------------------------- 25℃ Concentration of Testing Solution (NaCL)----------- 250PPm Feedwater PH value -------------------------------- 7.5-8 Recovery Rate -------------------------------------- 15% |
Operation Limits and Conditions Max. Working Pressure ------------------ 125Psi(0.86MPa) Max. Inflow Temperature ---------------- 45℃ SDI Max. Inflow SDI -------------------- 5 Residual Chlorine ----------------------- ﹤0.1PPm PH Range of Feedwater ----------------- 3-10 PH Range of Cleaning ------------------- 2-12 Max. Pressure Drop --------------------- 10Psi(0.07MPa) |
●Permeate flow for each RO membrane element would be 15% floating up and down according to the feed water under the standard test condition.
●Above data are test data for continuous running of 30 minutes.
●Provide personalized customized products.
|